NONMETALLIC TUBING ASSEMBLY. - Continued
NONMETALLIC TUBING ASSEMBLY. - Continued

M140 Chemical Agent Alarm \(Nsn 6665-01-083-2749\)
Page Navigation
  87    88    89    90    91  92  93    94    95    96    97  
img
. . .
ARMY TM 3-6665-329-13&P
AIR FORCE TO 11H2-18-1
This task covers:
Removal.
a.
Installation.
b.
INITIAL SETUP
Tools:
Electronic equipment tool
kit TK-100/G
Materials/Parts: Front ferrule Part No. 403-1-2 each
Back ferrule Part No. 404-1-2 each
a.
Removal.
(1) Remove lid (para 3-11b steps 1 thru 2).
(2) Unscrew screws (1) raise flowmeter bracket (2) and lock in position with hinge
spring bracket (3).
(3) Unscrew two nuts (4) and remove nonmetallic tubing assembly.
(4) Cut nonmetallic tubing (5) from metallic tube (6) and remove nut (4).
(5) Check nuts (4) for cracks or crossed threads.