NONMETALLIC TUBING ASSEMBLY.
NONMETALLIC TUBING ASSEMBLY. - Continued

M140 Chemical Agent Alarm \(Nsn 6665-01-083-2749\)
Page Navigation
  84    85    86    87    88  89  90    91    92    93    94  
img
TM 3-6665-329-13&P
(2) Cut nonmetallic tubing from metallic tube (3). Repeat procedures on other end of
nonmetallic tubing assembly.
(3) Force nut (1) from metallic tube (3) and lay aside.
NOTE
Reuse nuts.
(4) Check nuts (1) for cracks, crossed threads.
Installation.
b.
(1)
Slide nut (1), back ferrule (4), and front ferrule (5) onto metallic tub (3).
Insert metallic tube (3) into connecting fitting, and wrench tighten nut (1).
(2)
(3)
Repeat steps one and two for other end.
3-68