NONMETALLIC TUBING ASSEMBLY. - Continued
PRESSURE LOCK ANGLE VALVE.

M140 Chemical Agent Alarm \(Nsn 6665-01-083-2749\)
Page Navigation
  88    89    90    91    92  93  94    95    96    97    98  
img
.
TM 3-6665-329-13&P
b.
Installation.
(1) Slide nut (4), back (7), and front (8) ferrules on metallic tube assembly.
(2) Insert tube (5) into connecting fitting and wrench tighten nut (4).
(3) Repeat steps one and two for other end.
(4) Lower flowmeter and secure with screws.
(5) Perform Functional Test No. 9 (table 3-2).