FLOW ADJUST REGULATING VALVE.
DIAL INDICATING DIFFERENTIAL GAGE.

M140 Chemical Agent Alarm \(Nsn 6665-01-083-2749\)
Page Navigation
  91    92    93    94    95  96  97    98    99    100    101  
img
. .
TM 3-6665-329-13&P
3-24 FLOW ADJUST REGULATING VALVE.
Installation
b.
(1)
Insert FLOW ADJUST regulating valve (2) into panel assembly.
Install securing nut (6) and wrench tighten.
(2)
Install sealing nut (5) and wrench tighten.
(3)
Install knob (4) on end of FLOW ADJUST regulating valve (2) shaft.
(4)
Tighten setscrew (3).
(5)
Connect nonmetallic tubing assemblies as labeled and wrench tighten nuts (1)
(6)
(7)
Install front panel (para 3-11c steps 4 thru 8 and step 20).
Perform Functional Test No. 9 (table 3-2)
(8)
3-75