• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
FUNCTIONAL TEST PROCEDURES - Continued
Table 3-2. Functional Test Procedures - Continued

M140 Chemical Agent Alarm \(Nsn 6665-01-083-2749\)
Page Navigation
  30    31    32    33    34  35  36    37    38    39    40  
img
.
ARMY TM 3-6665-329-13&P
AIR FORCE TO 11H2-18-1
Table 3-2. Functional Test Procedures
Test
No.
Test
Procedure
1
Input Voltage
a.
Set test set METER SELECTOR switch to INPUT
VOLT position.
b.
Read ammeter. If it reads between 24 and
36 volts on the 40 volt (blue) scale, con-
tinue testing. If it does not, refer to
Troubleshooting paragraph 3-7.1.
c.
Power OFF.
3-14
Change 2


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.