TM 10-5410-228-10
2.21 OPERATOR PREVENTIVE MAINTENANCE CHECKS AND SERVICES - Continued.
Table 2-1. Operator Preventive Maintenance Checks and Services for CBPS - Continued
B - BEFORE D - DURING A - AFTER H - HOURLY
Location
Item
Item to
Not Fully Mission
No.
Interval
Check/Service
Procedure
Capable If:
Door cannot be
76
B
Ambulatory airlock
Ensure door opens and closes
door (outer)
and can be secured. Check for
opened/closed or vent
loose or missing hardware.
cannot be adjusted.
Check for missing airflow
Loose or missing
strip. Ensure self closing
hardware which
hinges work properly.
prevents normal
operation. Airflow strip
missing.
77
B
Ambulatory door
Unroll flap. Check flap for
Ambulatory door flap
flap
tears. Ensure flap is secured to cannot be sealed or is
torn.
ABS with fastener hook and
fastener loop tape. Check for
missing or damaged buckles.
Door cannot be closed
78
B
Tunnel Airlock
Ensure door and adjustable
and vent cannot be
Litter Patient
vents on door open and close
adjusted. Loose or
(TALP) door (outer) properly and can be secured.
missing hardware
Ensure retaining clamp and
latch function properly. Check which prevent normal
for loose or missing hardware. operation. Airflow strip
missing.
Check for missing airflow
strip.
79
B
TALP door timer
Ensure timer works properly.
80
B
TALP door flap
Unroll flap. Ensure flap is
TALP door flap cannot
secured to ABS with fastener
be sealed or is torn.
hook and fastener loop tape.
Check for tears. Check for
missing or damaged buckles.
81
B
Cable entry
Check for damaged zipper and
Cable entry port cannot
loose or separated seams.
be secured in closed
Verify cable entry is closed.
position.
82
B
Dump valve caps
Ensure all dump valve caps
More than one dump
(driver side only)
are secured tightly.
valve cannot be
secured.
83
B
ABS mounting
Check for loose or missing
Loose or missing
hardware
hardware securing ABS to
hardware which
LMS.
prevent normal
operation.
84
B
Ambulatory airlock
Ensure door opens and closes
Door cannot be closed/
door (inner)
and can be secured. Check for
opened. Loose, missing
loose, missing or damaged
or damaged parts which
parts. Check for missing
prevent normal
airflow strip.
operation. Airflow strip
missing.
2-44