TM 10-5410-228-10
Table 2-1. Operator Preventive Maintenance Checks and Services for CBPS - Continued
B - BEFORE D - DURING A - AFTER H - HOURLY
Location
Item
Item to
Not Fully Mission
No.
Interval
Check/Service
Procedure
Capable If:
53
B
Converter 1A4A14
Check for cracked or broken
Loose or missing
gages, indicators and controls.
components/hardware
Check for loose or missing
which prevent normal
hardware.
operation.
54
B
Check for cracked or broken
Loose or missing
gages, indicators and controls.
components/hardware
Check for loose or missing
which prevent normal
hardware.
operation.
55, sheet 6
B
Fire extinguisher
Check charge on fire
Fire extinguisher
extinguisher. If not charged,
missing or not charged.
notify supervisor. Note: If pin
has been pulled, fire
extinguisher is not charged.
56
B
Straps (each side
Check for missing or damaged
and roof)
straps. Check all straps for
security. Tighten as required.
57, sheet 7
B
Emergency exit
From inside LMS, unlock
Hatch cannot be opened
hatch
emergency exit hatch and
or closed. Damaged
ensure it opens and closes
seals. Loose or missing
smoothly. Check seals for
hardware.
damage. Check for loose or
missing hardware.
ECV
58
B
ECV
Perform operator's PMCS per
TM 9-2320-387-10.
HMT
59
B
HMT
Perform PMCS on HMT per
TM 9-2330-392-14&P.
60
B
HMT hookup
Ensure light cable, breakaway
Hookup and safety
chain and safety chains are
components are not
securely connected to ECV and
secured.
pintle hook is secured by
safety pin.
61
B
Stowed items
Check items are secured and
Items not secured.
ready for movement.
NOTE
This ends the before mission mobile mode PMCS.
2-41