TM 10-5410-228-10
Table 2-1. Operator Preventive Maintenance Checks and Services for CBPS - Continued
B - BEFORE D - DURING A - AFTER H - HOURLY
Location
Item
Item to
Not Fully Mission
No.
Interval
Check/Service
Procedure
Capable If:
106
B
TALP airlock
Check window for cracks, holes Window contains
and tears. Ensure flap is
cracks, holes or tears
secure.
greater than two
inches.
107
B
Insulation panels
Check for rips and tears.
(roof panels)
108
B
Windows (6)
Check all windows for cracks,
Windows contains
holes and tears. Ensure flaps
cracks, holes or tears
are secure.
greater than two
inches.
109, sheet 10
B
Air beams
Check for rips, punctures and
Rips, punctures or
loose or separated seams. Send
separated seams which
to unit level maintenance for
prevent proper
repair.
operation.
Check for disconnected tubing Air beams unable to be
110
B
Air beam manifold
or damaged valves. Listen and inflated due to air
and valves
leaks.
feel for air leaks. Hand
tighten manifold valves.
111
B
Tension relief strap Ensure tension relief strap is
secured to LMS.
112
B
ABS duct
Ensure ABS duct is secured to
LMS air supply port.
113
B
Light set extension
Check for deep abrasions, cuts, Any deep abrasions,
cables
exposed wires and damaged
cuts, exposed wires or
connectors.
damaged connectors.
Speaker cannot be
114
B
Speaker assembly
Check for loose or damaged
mounted properly.
hardware. Check cables for
Damage wires or pins.
damaged wires or connector
pins. Perform operation PMCS
per TM 11-5820-890-10-1,
TM 11-5820-890-10-3, or
TM 11-5820-890-10-6.
NOTE
It is vital that recirculation filter is fully serviceable. Unit maintenance should replace filter
element (126) in accordance with filter change criteria required in FM 3-11.4.
LMS - outer
115
B
Ladder
Check for loose or missing
hardware. Ensure rubber pads
are attached to feet.
2-47