STARTER AND CABLES - Continued
SUPPORTS - Continued

Recharging Unit, Carbon Dioxide Reciprocating Pump, Electric Motor Driven, Ac, 115Volt Single Phase, 60 Hz, 1Hp, 12681, 12681-2
Page Navigation
  52    53    54    55    56  57  58    59    60    61    62  
img
. .
TM 5-3655-214-13&P
4-17. SUPPORTS
This task covers:
a. Removal
d. Replacement
a. Cleaning
e. Installation
c
Inspection
INITIAL SETUP
Equipment
Condition
Condition Description
Applicable Configurations
Para
All
3-4
Equipment shut OFF
Test Equipment
None
Special Tools
Special Environmental Conditions
None
None
Materials/Parts
General Safety Instructions
Cleaning solvent
See Warnings and Cautions in
(Federal specification P-D-680)
this section
Bristle brush
Personnel Required
MOS 52C
LOCATION/ITEM
ACTION
REMARKS
REMOVAL
1. Supports
a. Refer to illustration following this sec-
tion and remove cotter pin (1), nut
(2), two flat washers (3) from stud on
bottle cradle (4).
b. Remove bottle cradle (4) from cradle
support (5).
4-35