Recharging Unit, Carbon Dioxide Reciprocating Pump, Electric Motor Driven, Ac, 115Volt Single Phase, 60 Hz, 1Hp, 12681, 12681-2
Page Navigation
  57    58    59    60    61  62  63    64    65    66    67  
img
TM 5-3655-214-13&P
4-18. TOOL BOX - Continued
LOCATION/ITEM
ACTION
REMARKS
CLEANING, INSPECTIONI
WARNING
Dry cleaning solvent, P-D-680 or P-S-661, used to clean parts is potentially dangerous
to personnel and property. Use in a well-ventilated area as the fumes are dangerous if
inhaled. Avoid repeated and prolonged skin con- tact. Do not use near open flame or
excessive heat. Flash point of solvent is 100F. - 138F. (38C. - 59C.)
2.
a. Clean tool box in an approved cleaning
solvent and dry with a clean, lint-free
cloth or compressed air.
b. Inspect the tool box for any obvious
damage.
REPAIR
3.
a. Replace a damaged tool box.
INSTALLATION
4.
a. Position tool box on skid base (6).
b. Install four screws (1), four lockwashers
(2), four flat washers (3) and four nuts
(4) that attach tool box (5) to skid (6).