TM 5-3655-214-13&P
This task covers:
a. Removal
d. Repair
b. Disassembly
e. Reassembly
c.
Cleaning, inspection
f.
Installation
INITIAL SETUP
Equipment
Condition
Condition Description
Applicable Configurations
Para
All
Pump shut down
Supply cylinder
Shutoff valve - closed
Test Equipment
Blow-off valve - open
None
Inlet bleed valve - open
Special Tools
Special Environmental Conditions
None
None
Materials/Parts
General Safety Instructions
Cleaning solvent
Observe Warnings
(Federal specification P-D-680)
and Cautions
Bristle brush
Personnel Required
MOS 52C.
LOCATION/ITEM
ACTION
REMARKS
REMOVAL
CAUTION
Make certain that pump has been shut down. Check that supply cylinder shutoff
valve Is closed. Check that pressure has been relieved by opening the blow-off
valve and inlet bleed valve.
1. Inlet hose
The filter is part of
the inlet tailpiece
Tailpiece assembly
a. Disconnect
assembly which is
installed on the inlet
hose.