Recharging Unit, Carbon Dioxide Reciprocating Pump, Electric Motor Driven, Ac, 115Volt Single Phase, 60 Hz, 1Hp, 12681, 12681-2
Page Navigation
  53    54    55    56    57  58  59    60    61    62    63  
img
TM 5-3655-214.13&P
4-17. SUPPORTS - Continued
LOCATION/ITEM
ACTION
REMARKS
REMOVAL
1. Supports
c.
Remove eight nuts (6), four screws (7),
(Continued)
eight flat washers (8) and eight lock
washers (9) attaching center support
(10).
d. Remove center support (10).
e. Remove two screws (11) two flat wash-
ers (12) two lock washers (13) from sup-
ports (17) and (18).
f.
Remove four screws (14), four flat
washers (15) and four lock washers (16)
from supports (17) and (18).
g. Remove supports (17) (18) and (5).
WARNING
Dry cleaning solvent, P-D-680 or P-S-661, used to clean parts is potentially dangerous
to personnel and property. Use in a well-ventilated area as the fumes are dangerous if
inhaled. Avoid repeated and prolonged skin con- tact. Do not use near open flame or
excessive heat. Flash point of solvent is 100F. - 138F. (38C. - 59C.)
CLEANING
2.
a. Cleaning
Clean all parts in an approved cleaning
solvent and dry with a clean lint-free
cloth or compressed air.
4-36