BUTT HINGE. - Continued
GROMMET

M140 Chemical Agent Alarm \(Nsn 6665-01-083-2749\)
Page Navigation
  80    81    82    83    84  85  86    87    88    89    90  
img
. . . .
TM 3-6665-329-13&P
This task covers:
a.
Removal,
Installation
b.
INITIAL SETUP
Tools:
Electronic equipment tool
kit TK-105/G
Removal
a.
(1) Remove lid (para 3-11 b steps 1 thru 2).
(2) Unscrew screw (1), and lift pneumatic line storage cover assembly (2).
(3) Remove screw (3) and latch (4).
Installation
b.
(1)
Position latch (4) under mounting hole with threaded boss down,
(2)
Secure latch (4) to panel assembly (5) with screw (3).
(3)
Close cover assembly (2) and secure with screw (1).
(4)
Install lid (para 3-11c step 20).