TM 5-6350-264-14&P-10NAVELEX EE 181-AA-OMI-110/E121 C-9412T.O. 31S9-2FSS9-1-10Table 5-2. Troubleshooting Procedures - ContinuedTroubleProbable causeCorrective action1.(Cont)a.(Cont)volts and connect negative lead tochassis (ground). Connect positivelead to power supply, TB2-3. Metershould indicate 20+1 vdc. Connectpositive lead to TB2-5. Meter shouldindicate 5 +0.25 vdc. Connect leadto TB2-2. Meter should indicate28 +2 vdc. Turn mode switch toSECURE and then TEST/RESET.f.Turn off switch S1 on top of power sup-ply. Remove PC boards Al through A6.Place thumb or finger under board ejectorand lift up until board pops out of recep-tacle at back of status processor. Thengrasp PC board and pull straight out.g.Inspect wires for loose or broken connec-tions at TB8-F through TB13-E, TB2-4,and P1/J12.h.Set multimeter to ohms and check forcontinuity (0 ohms) by connecting meterleads to the following points:J1-4 to TB8-F-1J1-4 to TB8-F-2via P1/J12-3J1-4 to TB8-F-3J1-12 to TB8-F-1J1-12 to TB8-F-2via P1/J12-4J1-12 to TB8-F-3J2-4 to TB9-A-1J2-4 to TB9-A-2via P1/J12-5J2-4 to TB9-A-3J2-12 to TB9-A-1J2-12 to TB9-A-2via P1/J12-7J2-12 to TB9-A-3J3-4 to TB10-B-1J3-4 to TB10-B-2via P1/J12-8J3-4 to TB10-B-3J3-12 to TB10-B-1J3-12 to TB10-B-2via P1/J12-9J3-12 to TB10-B-3J4-4 to TB11-C-1J4-4 to TB11-C-2via P1/J12-10J4-4 to TB11-C-3}}}}}}}5-11
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business