MOTOR PULLEY - Continued
MOTOR ASSEMBLY - Continued

Recharging Unit, Carbon Dioxide Reciprocating Pump, Electric Motor Driven, Ac, 115Volt Single Phase, 60 Hz, 1Hp, 12681, 12681-2
Page Navigation
  37    38    39    40    41  42  43    44    45    46    47  
img
. .
TM 5-3655-2141 3&P
4-13. MOTOR ASSEMBLY
This task covers:
a. Removal
c.  Replacement
b. Test
d. Installation
INITIAL SETUP
Equipment
Condition
Applicable Configurations
Para
Condition Description
All
3-4
Equipment is OFF
Test Equipment
Multimeter, 0 to 500V
SN 6625-00-998-6084
Special Tools
Special Environmental Conditions
None
None
Materials/Parts
General Safety Instructions
None
Observe Warnings and
Cautions
Personnel Required
MOS 52C
LOCATION/ITEM
ACTION
REMARKS
REMOVAL
1. Motor
WARNING
Make certain that the electrical power source has been disconnected.
a. Remove motor pulley.
b. Refer to illustration at end of this sec-
tion and disconnect wiring harness (1).
c.
Remove four nuts (2) one ground lug (3),
four flat washers (4) and four lock-
washers (5) that attach motor (6) to skid
base.
d. Remove motor.
4-20