  32    33    34    35    36  37  38    39    40    41    42  
img
TM 5-3655-214-13&P
4-11. PUMP PULLEY . Continued
LOCATION/ITEM
ACTION
REMARKS
CLEANING
1. Pump Pulley
(Continued)
WARNING
Dry cleaning solvent, P-D-680 or P-S-661, used to clean parts is potentially dangerous to personnel and property. Use in
a well-ventilated area as the fumes are dangerous if inhaled. Avoid repeated and prolonged skin contact. Do not use
near open flame or excessive heat. Flash point of solvent is 100F. - 138F. (38C. - 59C.)
2.
a. Clean all parts in an approved cleaning
solvent and dry with a clean, lint-free
cloth or compressed air.
INSPECTION
3.
a. Inspect pulley for cracks or obvious
damage.
REPAIR
4.
a. Replace a defective pulley.
INSTALLATION
5.
a. Install key (4) in pump shaft.
b. Install pulley (2) on pump (3).
c.
Install setscrew (1).
d. Install belt.
4-15