TM 5-3655-2141 3&P
4-13. MOTOR ASSEMBLY. Continued
LOCATION/ITEM
ACTION
REMARKS
TEST
2. Motor Capacitor
NOTE
It is not necessary to remove motor to remove and test capacitor.
a. Refer to illustration at the end of this
section.
b. Disconnect electrical leads from
capacitor (3)
c.
Remove capacitor (3) from motor (4)
d. Test capacitor for leaks or shorts on a
capacitor tester. Electrical character-
istics are:
60 HZ
REPLACEMENT
3.
a. Replace a defective capacitor.
b. Connect capacitor (3) electrical leads
and position in place on motor.
c.
Install cover (2) and screw (2)
INSTALLATION
4.
a. Place motor (6) on studs in skid base.
washers (4), one ground lug (3) and four
nuts (2) on studs in skid base.
c.
Connect wiring harness (1).
d. Install motor pulley.
4-21