TM 5-3655-214-13&P
Section II. TROUBLESHOOTING
3-2. TROUBLESHOOTING TABLE
a. This section lists the common malfunctions which may occur during operation of the recharging unit.
b. This manual cannot list all malfunctions that may occur. If a malfunction is not listed or is not corrected by listed
corrective actions, notify your supervisor.
TROUBLESHOOTING TABLE
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
1. MOTOR DOESN'T START.
Step 1. Check electrical connection.
Correct as required.
Step 2. Motor or Cable defective.
Refer to organizational maintenance for replacement.
Step 3. Starter damaged or defective.
Refer to organizational maintenance for repair or replacement.
2. MOTOR AND PUMP OPERATE, BUT FLUID DOES NOT FLOW.
Step 1. Check that the supply valve and the discharge shut off valve are in the open position.
Open valves as required.
Step 2. Check that the inlet bleed valve and the discharge blow-off valve are in the closed position.
Close valves as required.
Step 3. Slightly open inlet ble ed valve to permit visual check that the supply cylinder contains fluid.
Replace supply cylinder if fluid is not discharged from the inlet bleed valve.
Step 4. Inspect Tailpiece filter for clogged or damaged condition. See Section III.
Clean or replace filter as directed see in Section III.