TM 5-3655-214-13&P
3.4.
FILTER, TAILPIECE - MAINTENANCE INSTRUCTIONS - Continued.
LOCATION/ITEM
ACTION
REMARKS
DISASSEMBLY
2. Tailpiece assembly
Retainer and filter
b. Remove retainer and filter
WARNING
Cleaning solvent, Federal Specification P-D-680, is toxic and flammable. Use
solvent only in a well-ventilated area. Avoid prolonged breathing of solvent
vapors. Keep solvent away from open flame. Do not use in excessive amounts.
CLEANING, INSPECTION AND REPAIR
3. Filter
a. Clean with solvent and dry.
b. Inspect for:
clogged or damaged
c.
Report damaged filter to organizational
maintenance
ASSEMBLY
4. Tailpiece assembly
Filter and retainer
a. Reassemble.
INSTALLATION
5. Tailpiece assembly
a. Install the inlet tailpiece assembly.
3-6