• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 3-2. Functional Test Procedures - Continued
Table 3-2. Functional Test Procedures - Continued

M140 Chemical Agent Alarm \(Nsn 6665-01-083-2749\)
Page Navigation
  32    33    34    35    36  37  38    39    40    41    42  
img
ARMY TM 3-6665-329-13&P
AIR FORCE TO 11H2-18-1
Table 3-2. Functional Test Procedures (Cont)
Test
No.
Procedure
2
Nuclear Compen-
Read ammeter. If the meter reads between 12
g.
sating Circuit
and 16 volts dc on the 20 volt (green) scale,
Test (cont)
continue testing. If not, refer to Trouble-
shooting paragraph 3-7-4.
h.
Release OFFSET INPUT switch. Ammeter will
return to zero. If not, refer to Trouble-
shooting paragraph 3-7-4.
i.
Power OFF.
Remove jumper wires.
j.
k.
Return cables to CABLE STORAGE compartment.
Close and secure door.
3-16


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.