FUNCTIONAL TEST PROCEDURES - Continued
FUNCTIONAL TEST PROCEDURES - Continued

M140 Chemical Agent Alarm \(Nsn 6665-01-083-2749\)
Page Navigation
  28    29    30    31    32  33  34    35    36    37    38  
img
TM 3-6665-329-13&P
(2)
M10A1 Power Supply.
Place power switch (1) in OFF position.
(a)
(b)
Connect either the 115 volt connector or the 220 volt connector to an ac power source,
(c)
Connect cable (2) to test set INPUT POWER connector.
(d)
Set power switch (1) on power supply to agree with the ac power source used.
WARNING
DISCONNECT THE M10A1 POWER SUPPLY FROM THE POWER SOURCE BEFORE REMOVING THE
CARTRIDGE FUSES TO PREVENT POSSIBLE DEATH OR SERIOUS INJURY TO PERSONNEL.
3-12