Table 3-2. Functional Test Procedures - Continued
Table 3-2. Functional Test Procedures - Continued

M140 Chemical Agent Alarm \(Nsn 6665-01-083-2749\)
Page Navigation
  34    35    36    37    38  39  40    41    42    43    44  
img
ARMY TM 3-6665-329-13&P
AIR FORCE TO 11H2-18-1
Table 3-2. Functional Test Procedures (Cont)
Test
No.
Test
Procedure
4
Remote Alarm
a.
Connect jumper wire between socket D and E
Signal
of connector.
CONNECTOR
b.
Disconnect multimeter positive (red) lead
from test set, test point A.
c.
Set multimeter to 10 volt dc scale.
d.
Connect multimeter positive (red) lead to
TEST SET test point B.
Power ON.
e.
f.
Read multimeter. If it reads between 4.5 and
6.5 volts, continue testing. If it does not,
refer to Troubleshooting paragraph 3-7.4.
Power OFF.
g.
Remove jumper wire and disconnect multimeter
h.
leads.
i.
Disconnect cable from input power connector.
If used, unplug power supply from ac power
j.
source, and set aside.
Change 2
3-18