FRAME ASSEMBLY.
FRAME ASSEMBLY. - Continued

Technical Manual For Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
Page Navigation
  64    65    66    67    68  69  70    71    72    73    74  
img
Remove two self-locking nuts (1), flat washers (2), and hexagon head
Hexagon self-locking
screws (3). Remove pump frame support (4).
nuts (1)
Flat washers (2)
Hexagon head cap
screws (3)
Pump frame support (4)
Open tool box lid (5). Remove two hexagon self-locking nuts (6) and
Tool box lid (5)
machine screws (7). Remove pawl fastener (8) and attaching knob (9).
Hexagon self-locking
nuts (6)
Machine screws (7)
Pawl fastener (8)
Knob (9)
Remove four hexagon head cap screws (10), and two attach
Hexagon head cap
brackets (11) from center frame support (12).
screws (10)
Attach brackets (11)
Do not remove the four channel clamping nuts (13) from the inside of
Center frame support (12)
center frame support (12) vertical members unless they need to be
Channel clamping nuts (13)
replaced.