    SKID BASE SUBASSEMBLY. - Continued
    SKID BASE SUBASSEMBLY. - Continued

    Technical Manual For Decontaminating Apparatus: Power-Driven, Skid-Mounted, 500-Gallon, M12A1
    Page Navigation
      69    70    71    72    73  74  75    76    77    78    79  
    img
    2-68
    TM 3-4230-209-30&P
    2-20. SKID BASE SUBASSEMBLY (CONT).
    REMARKS
    LOCATION/lTEM
    ACTION
    Skid Base Subassembly/
    WARNING
    Unless it is securely blocked, never reach under the skid
    base subassembly while it is raised off the floor. Failure to
    comply may result in a crushed arm.
    Raise and block skid base subassembly in accordance with local policy.
    Remove two hexagon plain nuts (15), internal tooth lock washer (16),
    Hexagon plain nut (15)
    hexagon head cap screw (17) and flat washer (18). Remove ground
    Internal tooth lock
    washer (16)
    lead (7) and generator support (19).
    Hexagon head cap
    screw (17)
    Flat washer (18)
    Generator support (19)