TM 5-3740-218-13&P
4-31.
BATTERY CABLE REPLACEMENT
This task covers:
Removal
Installation
A.
INITIAL SETUP
Tools and Special Equipment:
General Safety Instructions:
Tool Kit, 5180-00-177-7033
WARNING
Equipment Condition:
All electrical switches must be OFF before disconnecting or
connecting battery cables. Shorting or arcing could cause
Reference
Condition Description
serious burns.
Paragraph 4-33
Battery Cover
Weldment Removed
B.
REMOVAL
WARNING
All electrical switches must be OFF before disconnecting battery cables. Shorting
or arcing could cause serious burns.
(1)
Disconnect two battery cables (1) from battery (2) by removing two locknuts (3).
(2)
Disconnect positive cable connection (4) from starter solenoid (5).
(3)
Disconnect ground cable connection (6) from engine (7).
(4)
Remove four adel clamps (8) from underside of engine mounting plate (9) by removing two nuts (10), four
washers (11), and two bolts (12).
4-72