BATTERY CABLE REPLACEMENT - Continued
SECONDARY HYDRAULIC MANIFOLD ASSEMBLY REPLACEMENT - Continued

Operator Manual Pesticide Dispersal Unit, Multicapability, Helicopter Slung
Page Navigation
  143    144    145    146    147  148  149    150    151    152    153  
img
. . .
TM 5-3740-218-13&P
4-32.
SECONDARY HYDRAULIC MANIFOLD ASSEMBLY REPLACEMENT
This task covers:
Removal
Installation
A.
INITIAL SETUP
Tools and Special Equipment:
Equipment Condition:
Tool Kit, 5180-00-177-7033
Reference
Condition Description
Paragraph 4-34
Hydraulic Reservoir
Drained
B.
REMOVAL
(1)
Remove electrical leads (1) from secondary hydraulic manifold 12 VDC coil (2).
(2)
Disconnect two hydraulic hoses from two quick-release fittings (3). Cap fittings (3) with two attached dust
caps (4). Cap open hydraulic lines.
(3)
Disconnect two hydraulic hoses from inlet (5) and outlet (6) 90-degree elbow fittings. Cap open hydraulic
lines.
(4)
Remove secondary hydraulic manifold assembly (7) from mounting platform (8) by removing two nuts (9),
four washers (10), and two holddown bolts (11).