BATTERY/HYDRAULIC ASSEMBLY REPLACEMENT - Continued
ALL ANGLE ISOLATOR REPLACEMENT

Operator Manual Pesticide Dispersal Unit, Multicapability, Helicopter Slung
Page Navigation
  137    138    139    140    141  142  143    144    145    146    147  
img
.
TM 5-3740-218-13&P
BATTERY/HYDRAULIC ASSEMBLY REPLACEMENT (CONT)
C.
INSTALLATION
WARNING
Battery/hydraulic assembly is very heavy. Use two persons when lifting or moving
assembly to prevent personal injury.
(1)
Using two persons, install battery/hydraulic assembly (1) with secondary hydraulic manifold toward rear of
bucket assembly.
(2)
Align two side supports (2) with four bucket leg weldment unions (3) and install four washers (4), four bolts
(5), four washers (4), and four nuts (6).
(3)
Connect electrical leads (7) to secondary hydraulic manifold 12 VDC coil (8).
(4)
Remove cap and connect return hydraulic hose to outlet 90-degree elbow fitting (9).
(5)
Remove cap and connect pressure hose from primary hydraulic manifold to inlet 90-degree elbow fitting
(10).
(6)
Install battery (11) (para 4-33).
4-70