TEMPERATURE SENSOR (INLET TEMP). - Continued
HOUSING SUBASSEMBLY. - Continued

M140 Chemical Agent Alarm \(Nsn 6665-01-083-2749\)
Page Navigation
  118    119    120    121    122  123  124    125    126    127    128  
img
. . .
TM 3-6665-329-13&P
3-46 HOUSING SUBASSEMBLY.
This task covers:
Removal.
a.
Installation.
b.
INITIAL SETUP
Tools:
Electronic equipment tool
kit TK-105/G
a.
Removal.
(1) Remove lid (para 3-11b steps 1 thru 3).
(2) Loosen screw (1) and open cable cover assembly (2).
(3) Remove paddle temperature assembly (3) from housing subassembly by turning
collar counterclockwise.
(4) Remove remaining cables fro CABLE STORAGE compartment.
(5) Remove four screws (4) and Iockwashers (5).
(6)
Lift housing subassemlby (6) from
3-102