CIRCUIT CARD ASSEMBLY.
DUMMY CONNECTOR (DETECTOR POWER CABLE). - Continued

M140 Chemical Agent Alarm \(Nsn 6665-01-083-2749\)
Page Navigation
  121    122    123    124    125  126  127    128    129    130    131  
img
. . .
TM 3-6665-329-13&P
3-48 DUMMY CONNECTOR (DETECTOR POWER CABLE).
This task covers:
Removal.
a.
Installation.
b.
INITIAL SETUP
Tools:
Electronic equipment tool
kit TK-105/G
Removal.
a.
(1) Remove lid and panel assembly (para 3-11b steps 1 thru 8).
(2) Unscrew screw (1) and open cable cover assembly (2).
(3) Remove cable labeled detector power (3) from dummy connector (7).
(4) Remove remaining cables from CABLE STORAGE.
(5) Remove four screws (4), nuts (5), Iockwashers (6).
(6) Remove dummy connector (7).