• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
HOUSING INDICATOR.
ROTARY SWITCH (ALARM TEST).

M140 Chemical Agent Alarm \(Nsn 6665-01-083-2749\)
Page Navigation
  100    101    102    103    104  105  106    107    108    109    110  
img
. . . . .
TM 3-6665-329-13&P
3-31 TOGGLE SWITCHES.
This task covers:
Removal.
a.
Installation.
b.
INITIAL SETUP
Tools:
Electronic equipment tool
kit TK-100/G
NOTE
This procedure applies to all test set toggle switches.
Removal.
a.
(1) Remove lid and panel assembly (para 3-11b steps 1 thru 8).
(2) Remove wires (1). If removing OFFSET INPUT switch, unscrew three screws (2),
Iockwashers (3) and remove circuit card assembly.
(3) Remove nut (4) and switch (5).
Installation.
b.
(1) Remove nut (4).
(2) Adjust nut (6) until threads extend approx. 1/16 inch above panel assembly.
(3) Secure toggle switch (5) with nut (4).
(4) Using FO-2 as a guide, connect wires (1).
(5) If OFFSET INPUT switch was replaced, install circuit card assembly with three screws
(2) and Iockwashers (3).
(6) Install panel assembly and lid (para 3-11c steps 4 thru 8 and 20).
3-84