This task covers:
Removal.
a.
Installation.
b.
INITIAL SETUP
Tools:
Electronic equipment tool
kit TK-105/G
Removal.
a.
(1) Remove lid and panel assembly (para 3-11 b steps 1 thru 8).
(2) Unscrew screw (1) and open pneumatic line storage cover (2).
(3) Remove two screws (3), nuts (4), and Iockwashers (5), securing door to butt hinge (6).
(4) Remove three screws (7), nuts (8), and Iockwashers (9) and butt hinge (6).
Installation.
b.
(1) Install butt hinge to panel assembly using three screws (7), Iockwashers (9),
and nuts (8).
NOTE
Before tightening screws insure that cover (2) is aligned.
3-62