  18    19    20    21    22  23  24    25    26    27    28  
img
. . . .
SECTION VI
DIRECT AND GENERAL SUPPORT AND
DEPOT MAINTENANCE INSTRUCTIONS
covers (16) with the holes in the key
31. General
guide (9) and secure with the screws (18)
Direct  support,  general  support,  and  depot
and nuts (5).
maintenance personnel are authorized to perform all the
(f) Aline the holes in the screw covers (16)
maintenance services performed by operator and
with the holes in the adjusting screw
organizational maintenance personnel. In addition, they
retainers (11) and fasten with the screws
are authorized to perform the maintenance cited in the
(15 and 17).
succeeding paragraphs.
32. Direct Support Maintenance
b. Ball Assembly.
a. Shield Adjustment Assembly.
(1) General.
Direct  support  maintenance
(1) General.
Direct  support  maintenance
personnel are authorized to replace the four
personnel are authorized to replace the
adjusting screws (13, fig. 15).
plunger collar (3, fig. 16) and plunger spring
(2) Removal.
(7).
(a) Remove the four screw covers (16) by
(2) Removal.
removing the two screws (15 and 17) and
(a) Remove the ball assembly (para. 28b).
the nut (5) and screw (18) in each cover.
(b) Stand the ball (9, on a flat surface with
(b) Remove  the  screw  (8)  from  each
the wrench holder plate (5) uppermost
adjusting screw retainer (11).
and remove the lock bolt screw (2).
(c) Unscrew the adjusting screw (13) from
(c) Remove the two plate screws (1) and
the adjusting key (14).
carefully lift the wrench holder plate (5)
(d) Remove the adjusting knob (10) from the
off the ball (9).
adjusting screw (13) by removing the pin
(d) Remove the plunger collar (3) from the
(12).
plunger (8) by removing the pin (4).
(e) Slide the adjusting screw (13) from the
(e) Remove the plunger (8), plunger spring
adjusting screw retainer (11).
(7), and plunger housing (6) from the
(3) Installation.
wrench holder plate (5).
(a) Slide the adjusting screw (13) into the
(3) Installation.
adjusting screw retainer (11).
(a) Install the plunger housing (6) in the
(b) Aline the hole in the adjusting knob (10)
wrench holder plate (5) and insert the
with the hole in the adjusting screw (13)
plunger spring (7) and plunger (8) in the
and fasten with the pin (12).
plunger housing (6).
(c) Screw the adjusting screw (13) into the
(b) Install the plunger collar (3) over the
adjusting key (14).
plunger (8) and aline the holes in the
(d) Aline the hole in the adjusting screw
collar and plunger. Secure col-
retainer (11) with the hole in the shield
and fasten the retainer to the shield with
the screw (8).
(e) Aline the holes in each of the four screw
TAGO 5013-A 25