lar (3) to the plunger (8) with the pin (4).
33. General Support Maintenance
(c) Position the wrench holder plate (5) on
General support maintenance personnel are
the ball (9) so that the plunger (8) is
authorized to overhaul the M1 valve replacement
alined with the lock bolt (10). Screw the
mechanism.
The procedures described under
lock bolt screw (2) through the wrench
operator's,
organizational,
and
direct
support
holder plate into the hole in the lock bolt.
maintenance are applicable to overhaul.
(d) Unlock the lock bolt (10) and secure the
34. Depot Maintenance
wrench holder plate (5) to the wrench
Depot maintenance personnel are authorized to
holder (12) with the two plate screws (1).
perform all the maintenance functions previously
described. No special maintenance is designated for
depot maintenance personnel.
TAGO 5013-A 26