TM 10-8415-208-123-9. EMERGENCYBREATHINGAPPARATUS(EBA)MAINTENANCEINSTRUCTIONS. (CONT)b.Installing.(1) Position new cylinder (5) on the EBA.(2) Thread coupling nut (3) onto cylinder valve (1).(3) Connect cylinder clamp (4).(4) Using a wrench, tighten coupling nut (3).(5) Close the regulator valve (2).(6) Leak test the EBA, Refer to paragraph 3-9.3.3.3-9.2.4 Removing/InstallingCushionCover.a.Removing(1) Unsnap Straps (1) and (2).(2) Pull straps (1) out of support assembly (3).(3) Pull cushion cover (4) clear of the EBA.3-44