TM 10-8415-208-12
3-9. EMERGENCY BREATHING APPARATUS (EBA) MAINTENANCE INSTRUCTIONS. (CONT)
(2)
Apply new anti-seize tape to elbow (5) threads and screw elbow (5) into new regulator (8).
(3)
Apply new anti-seize tape to male connector (2) threads and screw into elbow (5).
(4)
Attach new regulator (8) to bracket (9) using washers (7) and screws (6).
(5)
Connect air line coupling (3) to male connector (4).
(6)
Align elbow (5) and connect air line coupling (1) to male connector (2).
(7)
Perform steps b.(1) through b.(5), paragraph 3-9.2.3, to install the cylinder.
(8)
Leak test the EBA and perform the Static Pressure Test and Air Flow Performance Test.
Refer to paragraphs 3-9.3.1 through 3-9.3.3.
3-9.2.7 Removing/Installing Regulator Diaphragm.
a.
Removing.
(1)
Perform steps a.(1) through a.(6),paragraph 3-9.2.3, to remove the cylinder.
(2)
Perform steps a.(2) through a.(5), paragraph 3-9.2.6, to remove the regulator.
(3)
Unscrew regulator cover (1) from regulator (2).
(4)
Remove diaphragm spring (3).
(5)
Remove diaphragm (4) from regulator (2).
3-48