TM 10-8415-208-12
t.
Slide position indicator label (9) onto on/off switch (12).
u.
Put locking nut (8) on the on/off switch (12) and tighten.
v.
Position battery (4) and secure it in place using hook and pile fastener tape strap (3).
w.
Connect battery connector (1) to pump connector (2).
3-9.
EMERGENCY BREATHING APPARATUS (EBA) MAINTENANCE INSTRUCTIONS.
This task covers:
a.
Inspection
c.
Testing
b.
Replacement
d.
Cleaning
INITIAL SETUP
Tools
Portable Regulator Tester (Appendix B, Section II, item 7)
MSA Special Tool (Appendix B, Section III, item 19)
Technical Manual (Appendix B, Section III, item 20)
Pliers (Appendix B, Section III, item 23)
Screwdriver (Appendix B, Section III, item 32)
Screwdriver (Appendix B, Section III, item 33)
Screwdriver (Appendix B, Section III, item 35)
Wrench (Appendix B, Section III, item 38)
Wrench (Appendix B, Section III, item 40)
Wrench (Appendix B, Section III, item 41)
Wrench (Appendix B, Section III, item 42)
Wrench (Appendix B, Section III, item 43)
Wrench (Appendix B, Section III, item 44)
Wrench (Appendix B, Section III, item 45)
Wrench (Appendix B, Section III, item 46)
Wrench (Appendix B, Section III, item 47)
Brush (Appendix D, Section II, item 5)
Materials/Parts
Spare/Repair Kit (Appendix B, Section II, item 12)
Breathing Tube (Appendix B, Section III, item 5)
Air Cylinder (Appendix B, Section III, item 10)
Filter Cartridge (Appendix B, Section III, item 13)
Preformed Packing (Appendix B, Section III, item 28)
Battery (Appendix D, Section III, item 4)
Cleaner/Sanitizer (Appendix D, Section II, item 8)
Hose Clamp (Appendix D, Section II, item 29)
3-39