TM 10-8415-208-123-9.EMERGENCYBREATHINGAPPARATUS(EBA)MAINTENANCEINSTRUCTIONS. (CONT)WARNINGPersonnel contamination hazard. If the EBA filter cartridge is suspected to be contaminated with chemicalagent, it must be removed under engineering controls to prevent the spread of contamination. Failure touse engineering controls could result in personnel injury or death due to contamination.(1)Unscrew air supply end (1) of filter housing (2).NOTEThe filter cartridge will be replaced after each use or every 6 months, whichever comes first.(2)Unscrew used filter cartridge (3).(3)Remove preformed packing (4) and gasket (5).NOTEDent the filter cartridge threads to prevent reuse.(4)Place used filter cartridge (3), preformed packing (4) and gasket (5) into a plastic disposal bag. Twist theend closed and tape it securely for an airtight seal.(5)Dispose of the used filter cartridge (3), preformed packing (4) and gasket (5) in accordance with local SOP.b.Installing.(1)Brush clean the threads of air supply end (1) and filter housing (2).(2)Wipe the inside of air supply end (1) and filter housing (2) clean of all dirt.(3)Install a new preformed packing (4) and gasket (5).(4)Screw in a new filter cartridge (3).(5)Screw air supply end (1) onto filter housing (2).(6)Leak test the EBA. Refer to paragraph 3-9. 3. 3.3-9.2.3Removing/InstallingCylinder.a.Removing.3-42
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business