TM 10-5410-228-24
This task covers:
a. General
c. Installation
b. Removal
INITIAL SETUP
Tools/Test Equipment:
Equipment Conditions:
Shop Equipment, Automotive Maintenance and
Power shut off, power panel and rear control panel
tagged.
Shop Equipment: Electrical Equipment
ECV battery cable disconnected
(see TM 9-2320-387-24-1).
External power cable disconnected.
Raceway covers and retainers removed
Materials/Parts:
References:
TM 9-2320-387-24-1
TM 55-1500-323-24
CBPS contains high electrical currents. To prevent electrical shock when working on
electrical system, ensure that power cable is disconnected from power panel and ECV
batteries are disconnected per TM 9-2320-387-24-1. Tag power panel and battery area with
sign that states that the power must remain OFF while work is being performed.
Remove jewelry and observe all safety rules for working around high voltage.
NOTE
Remove/disassemble only to the extent necessary to remove or replace defective
assemblies/components. Use standard maintenance shop practices/procedures.
a. General
The following table contains information necessary to remove and replace cables. The headings found
in the table are described as follows:
(1)
Cable No. The W number found on the cable is listed in this column.
(2)
Connectors. Under the connectors column is a listing of each connector on the cable and its
mating location.
(3)
Comments. This column contains additional information that could help in the removal or
installation of the cable.