TM 10-5410-228-24
This task covers:
a. Removal
c. Assembly
b. Disassembly
d. Installation
INITIAL SETUP
Tools/Test Equipment:
Equipment Conditions:
Shop Equipment, Automotive Maintenance and
Power off, power panel tagged.
Cover assembly opened on electrical equipment
Shop Equipment: Electrical Equipment
References:
TM 9-2320-387-24-1
Materials/Parts:
CBPS contains high electrical currents. To prevent electrical shock when working on
electrical system, ensure that power cable is disconnected from power panel and ECV
batteries are disconnected per TM 9-2320-387-24-1. Tag power panel and battery area with
sign that states that the power must remain OFF while work is being performed.
Remove jewelry and observe all safety rules for working around high voltage.
NOTE
Remove/disassemble only to the extent necessary to remove or replace defective
assemblies/components. Use standard maintenance shop practices/procedures.
(1)
Loosen two screw lock assemblies (1) securing connector strain relief (2) to connector receptacle
(3) and disconnect connector strain relief (2).
(2)
Remove twelve nuts (4), four lockwashers (5) and twelve flat washers (6) securing temperature
control unit (7) to support enclosure assembly (8). Discard four lockwashers (5).
b. Disassembly
There is no repair of the temperature control unit (7).
c.
Assembly
There is no repair of the temperature control unit (7).
(1)
Secure temperature control unit (7) to support enclosure assembly (8) with twelve flat washers
(6), four new lockwashers (5) (Item 15, Appx E) and twelve nuts (4).
(2)
Secure connector strain relief (2) to connector receptacle (3) with two screw lock assemblies (1).