T.O. 33B-1-1Figure 1-17.Point of Incidence Determination with IIW Block1.8.2.6.2AngleBeamPointofIncidence(MiniatureAngleBeamBlock).NOTEThe point-of-incidence as determined in accordance with these proceduresmay not correspond with the point-of-incidence placed on the search unit bythe search unit manufacturer.a.Move the search unit back and forth from the curved surface at R-2 (see Figure 1-18) the peak signalfrom R-2 is obtained.b.The search unit point-of-incidence now coincides with the line marked ‘‘0’’ on the block. Mark thepoint-of-incidence on the side of the search unit.Figure 1-18.Determination of Point of Incidence with Miniature Angle Beam BlockChange 31-65
Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business