TM 5-3740-218-13&P
This task covers: Disassembly Cleaning Solenoid Repair Flow
Regulator Repair
Assembly
A. INITIAL SETUP
Tools and Special Equipment:
General Safety Instructions:
Tool Kit, 5180-00-177-7033
Materials/Parts:
WARNING
O-Ring
Death or serious injury could result
by repeated and/or prolonged
Kit, Parts Repair
breathing and/or skin contact of
drycleaning solvent (P-D-680). Use in
Kit, Parts Repair
a well-ventilated area. Do not use
near open flame or in excessive heat.
Solvent, Drycleaning,
The flash point of this solvent is
P-D-680
100F-183F (38C-59C).
Sealant, Thread
Compressed air used for cleaning and
drying purposes shall not exceed 30
psi. Use only with effective chip
Equipment Condition:
guarding and personal protective
equipment (goggles/shield, gloves,
Reference
Condition Description
etc.). Flying debris could cause
Secondary Hydraulic
personal injury debris could caus
e
Manifold Removed