STARTER MOTOR REPAIR - Continued
ENGINE AND PUMP ASSEMBLY HYDRAULIC PUMP ASSEMBLY REPAIR - Continued

Operator Manual Pesticide Dispersal Unit, Multicapability, Helicopter Slung
Page Navigation
  244    245    246    247    248  249  250    251    252    253    254  
img
. . . . . . .
TM 5-3740-218-13&P
5-8. ENGINE AND PUMP ASSEMBLY HYDRAULIC PUMP ASSEMBLY REPAIR
This task covers: Disassembly  Inspection
Repair  Assembly
A. INITIAL SETUP
General Safety Instructions:
Tools and Special Equipment:
Tool Kit, 5180-00-177-7033
Shop Equipment, 4910-00-754-0654
Plastic Hammer/Mallet
WARNING
Death or serious injury could result
Materials/Parts:
by repeated and/or prolonged
Kit, Parts Repair
Appendix E, Item 25
breathing and/or skin contact of
drycleaning solvent (P-D-680). Use in
Solvent, Drycleaning,
Appendix E, Item 59
a well-ventilated area. Do not use
P-D-680
near open flame or in excessive heat.
The flash point of this solvent is
File, Emery Stone
Appendix E, Item 7
100F-138OF (38C-59C).
Fluid, Hydraulic
Appendix E, Item 10
Equipment Condition :
Reference
Condition Description
Paragraph 4-27
Hydraulic Pump
Removed
5-17