TM 5-3740-218-13&P
SECONDARY HYDRAULIC MANIFOLD ASSEMBLY REPAIR (CONT)
C. CLEANING
WARNING
Death or serious injury could result by repeated and/or prolonged
breathing and/or skin contact of drycleaning solvent (P-D-680). Use in a
well-ventilated area. Do not use near open flame or in excessive heat.
The flash point of this solvent is 100F-183F (38 C-59C).
(1) Flush out manifold with drycleaning solvent (item 59, Appendix E).
WARNING
Compressed air used for cleaning and drying purposes shall not exceed
30 psi. Use only with effective chip guarding and personal protective
equipment (goggles/shield, gloves, etc.). Flying debris could cause
personal injury.
(2)
Dry manifold with low-pressure air.
(3)
Clean valves with drycleaning solvent (item 59, Appendix E).
5-24