Table 5-3. Direct and General Support Maintenance Troubleshooting (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ENGINE DOES NOT TURN OVER (Continued)
(3)
If the wire conducts a current, go to Step 2f.
(4)
If the wire does not conduct electricity or the meter fluctuates, replace it and go to Step 2f.
(5)
If any of the wires or insulation are frayed, broken, or cracked, replace them and go to Step 2f.
Figure 5-55. Fuse Holder Location
e. Check the fuse.
(1)
Unscrew the fuse holder and check the fuse.
(2)
If it is ok, screw the fuse holder back together and go to Step 3.
(3)
If the fuse is blown, replace it and screw the fuse holder back together. Go to Step 2f.
f. Start the engine.
(1)
If the engine starts, the problem is solved.
(2)
If the engine does not start, go to Step 3.
Step 3. Check the starter.