TM 5-3740-214-14
Table 5-3. Direct and General Support Maintenance Troubleshooting (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
ENGINE DOES NOT TURN OVER (Continued)
(5)
If the specific gravity is below 1.150 in any one cell, replace the battery and go to Step 2d.
(6)
If the specific gravity in one cell is more than 0.050 less than the other cells and will not charge
to more than a 50% charge, replace the battery and go to Step 2d.
c. Charge the battery.
(1)
If the battery holds a charge, return it to the battery box and go to Step 2d.
(2)
If the battery does not hold a charge, replace it and go to Step 2d.
Figure 5-54. Aerosol Generator Wiring Diagram
Battery cables.
The wire between the battery and the start button.
The wire between the start button and the ignition switch.
The wire between the ignition switch and the alternator.
(1)
Connect a meter lead to each end of the wire being tested.
(2)
Wiggle the wire.
5-49