FILTER, TAILPIECE - MAINTENANCE INSTRUCTIONS - Continued
CHAPTER 4 ORGANIZATIONAL MAINTENANCE INSTRUCTIONS

Recharging Unit, Carbon Dioxide Reciprocating Pump, Electric Motor Driven, Ac, 115Volt Single Phase, 60 Hz, 1Hp, 12681, 12681-2
Page Navigation
  17    18    19    20    21  22  23    24    25    26    27  
img
. . .
TM 5-3655-214-13&P
3-4. FILTER, TAILPIECE - MAINTENANCE INSTRUCTIONS - Continued
Inlet Tailpiece Assembly, Removed and Disassembled
3-5. BELT
This task covers:
a. Removal
c.
Installation
b. Inspection
INITIAL SETUP
Equipment
Condition
Applicable Configurations
Para
Condition Description
All
3-4
Pump shut down
Test Equipment
None
Special Tools
Special Environmental Conditions
None
None
Materials/Parts
General Safety Instructions
None
Motor is off.
Personnel Required
MOS 52C.
LOCATION/ITEM
ACTION
REMARKS
REMOVAL
1. Belt Inspection Cover
a. Remove screws
The belt is installed
on the motor pulley
b. Remove cover
pump pulley and
covered with a
guard.
INSPECTION
2.
a. Check belt tension by pressing on belt
for slight deflection. If belt tension re-
quires adjustment report to organi-
zational maintenance.
INSTALLATION
3.
b. Replace inspection cover and reinstall
screws.
3-8