TM 3-6665-329-13&P
3-52 BRANCHED WIRING HARNESS (CONT).
h. Solder all tinned tipped wires, except wires to be connected to circuit
card asembly (14).
i. Install connector J4 (31) using two screws (28), lockwashers (30) and nuts (29).
NOTE
Be sure ground lug is installed on one mounting screw of connector J1.
j. Install connector J1 (27) using two screws (24), Iockwashers (26) and nuts (25).
k. Connect wires to toggle switches (17), (18), (19), (20), (21), and (22).
l. Slide heat shrinkable sleeving insulation (item 3, app D) unto wires to be connected
m
Solder wires to SYNC PULSE lamp leads as labeled.
n. Install circuit card assembly (14) using three screws (15) and Iockwashers (16).
o. Solder wires to circuit card assembly (14).
Connect wires to TB2.
P.
q. Connect wires to TB1 (7).
r. Install TB1 with four screws (4), lockwashers (5) and nuts (6).
s. Install circuit card assembly. (Para 3-47b steps 1 and 2).
Functional Test.
c.
3-120