TM 3-6665-329-13&P
3-54 FLOWRATE METER.
This task covers;
Removal.
a.
Installation.
b.
INITIAL SETUP
Tools:
Electronic equipment tool
kit TK-100/G and TK-105/G
a.
Removal.
(1) Remove lid and panel assembly. (para 3-11b steps 1 thru 8).
(2) Remove nonmetallic tubing assemblies (1).
(3) Remove elbow (2).
(4) Remove adapter (3).
(5) Squeeze and pull protective cover (4).
(6) Remove two screws (5), nuts (6) and washers (7) from flowrate meter (8) and remove
flowrate meter from bracket (9).
3-123