BRANCHED ELECTRICAL SPECIAL PURPOSE CABLE ASSEMBLY (PUMP POWER). - Continued
BRANCHED ELECTRICAL SPECIAL PURPOSE CABLE ASSEMBLY (CHASSIS TEST). - Continued

M140 Chemical Agent Alarm \(Nsn 6665-01-083-2749\)
Page Navigation
  126    127    128    129    130  131  132    133    134    135    136  
img
. . .
TM 3-6665-329-13&P
3-50 BRANCHED ELECTRICAL SPECIAL PURPOSE CABLE ASSEMBLY (CHASSIS TEST).
This task covers:
Removal.
a.
Installation.
b.
INITIAL SETUP
Tools:
Electronic equipment tool
kit TK-100/G and TK-105/G
Removal
a.
(1) Remove lid and panel assembly. (para 3-11b steps 1 thru 8).
(2) Loosen cable clamp screws (1).
(3) Cut wire ties.
(4) Remove four screws, (2), Iockwashers (3) and nuts (4).
(5) Remove terminal board (5)
(6) Remove wires 9, 5, 8, 138, and 139 from TB1 (5).
(7) Remove wires 3 and 4 from S2 (6).
(8) Remove wire 2 from S6 (7).
(9) Remove wire 1 from circuit card assembly (8).
(10) Remove wire 6 from S4 (9).
3-110