This task covers:
a.
Removal.
b.
Installation,
INITIAL SETUP
a.
Removal.
(1) Remove lid (para 3-11b steps 1 and 2).
(2) Push in and release three fasteners (1) and open accessory shelf (2).
(3) Unscrew screw (3).
(4) Remove screw (4), two washers (5), locknut (6) and clamp (7).
b.
Installation.
(1) Install screw (3) on accessory shelf (2).
(2) Position clamp (7) in mounting position. Secure screw (4), two washers (5) and locknut (6).
(3) Tighten screw (3),
(4) Install lid (para 3-11c steps 19 and 20).